Western Cape Branch Engineering Bulletin: Published
October 2009
Download the complete PDF version
October 2009
- Editorial
- Local Branch News
- Safenet Thought for the day - New
Pressure Equipment Regulations
- Safenet Thought for the day - New
Pressure Equipment Regulations (Follow on)
- GCoC Examination Q&A: OHS Act Exam Paper.
Nov 2004 (8.1 & 8.2)
- GCoC Examination Q&A: Plant Engineering Exam paper
June 2009 (4)
- Electricity in Cape Town - Part
5. Graff Electric Lighting Works - A Glimmer of Light:
by Dennis Palser, Past City Electrical Engineer of Cape Town
- Engineers Pick Up Lines
- You might be an Engineer
if.............
Welcome to another edition of the Western Cape News Bulletin. This
quarter we have our normal articles in this news bulletin. GCC exam
questions and answers and Part 5 of the article on the Electrification
of Cape Town, titled “Lighting up the Fairest Cape 1895 to 1995”.
Further, we wish to call your attention to two articles / incidents
which are worthy to note but have very large document sizes, and as such
– should anyone want a copy of the said documents, please contact me and
I will forward to you.
The first is the “Accident at Russia’s Biggest Hydroelectric” power
point or pdf presentation. This presentation is 5Mb big and therefore
too big to send to dial up connections. The second is a copy of the new
“Pressure Equipment Regulations” referred to in the two SafeNet Africa
articles in the bulletin. Its size is 1.5Mb. I trust that you will find
the content of this news bulletin interesting enough to pass on to your
colleagues and friends.
Chris Schnehage
Tel: 083 326 8023 email:
chris@icmeewc.co.za
Editor: Henriette Venter email:
vencon@netactive.co.za
Activities of the branch since last news bulletin were as follows:
- Things have been a bit hectic the last few months and
presentations and visits that were being arranged did not take place
due to various reasons (again!).
- June 30 – talk on “the current trends in solar energy options,
the benefits and technical options plus examples of some of the
applications (large scale down to domestic) that are being
implemented in SA and abroad”. 11 members attended. Very interesting
topic.
- July 28 – presentation on infrared testing of critical
electrical machinery. 15 members attended.
Planned events that did not happen:
- August – a visit to a water purification systems manufacturer in
Strand – GrahamTech.
- September –talk on pump selection and solutions.
The following are items that are being planned for presentation:
- The above two items in October and November respectively.
October 13 - Talk on an energy saving technology called “Power
Optimisa”.
Should any of our members receive this news letter by snail mail and
would like to get it electronically – or you notice that you are not
getting invitations to our talks and visits, please be so kind as to
forward your email address to me to the email address below.
Thank you!
If you know of a presentation or technical visit that we could arrange
for our members, please also pop me an email and we will see what we can
do.
Ciao for now!
Chris Schnehage
Tel: 083 326 8023
Email: chris@icmeewc.co.za
On the 15th of July the Department of Labour promulgated new Pressure
Equipment Regulations, 2009 which will replace the existing Vessels
under Pressure Regulations (VUP Reg) as promulgated on the 4th of
October 1996. The bulk of the new requirements will come into effect on
the 1st of October 2009.
In this Safety Thought we will attempt to highlight some of the more
important or new provisions contained in Government Gazette notice
number R734 dated the 15th of July 2009:
- Currently the regulations require that pressure vessels be
inspected and tested by Department of Labour Approved Registered
Persons. Any person with the necessary training or experience could
register for this purpose and it is not uncommon to find that most
of these companies are very small and may even consist of the
registered person, an assistant and their “bakkie”. The current
legislation also makes provision for the registration of Department
of Labour Approved Inspection Authorities (AIA’s) for pressure
vessels. These AIA’s are normally regarded as more competent and
their services would therefore mainly be used when making
modifications to vessels, overseeing the manufacturing process and
when having to perform more complex inspections and / or tests. The
Department of Labour regards these AIA’s so competent that employers
could approach them for exemption from some certain legal
requirements contained in the old VUP Regulations. This in all other
health and safety regulations would be a task that may only be
performed by the Department of Labour.
The new regulations only makes provisions for AIA’s and no mention
is being made of the Registered Persons. It could therefore be
assumed that some Registered Persons will register to become AIA’s.
To be registered as an AIA one needs to be accredited by an
international or South African Accreditation Authority such as SANAS.
The cost and paperwork associated with such an accreditation process
may just be too much for most persons currently registered as
Registered Persons and the most likely outcome would be that some
Registered Persons will start performing tasks under the supervision
of an existing AIA. It is however my opinion that some currently
approved Registered Persons would most probably leave the industry;
- The definition of a pressure vessel has been changed
substantially in that it now states that it is any housing designed
and manufactured to contain a pressure equal or greater than 50kPa.
Although the new legislation excludes certain vessels such as
aerosol dispensers, tyres and air receivers on vessels it is clear
that many more vessels will now have to be subjected to inspections
and tests due to them being regarded as pressure vessels. A typical
example would be hot water cylinders with a water capacity of more
than 450 litres which operates at a maximum pressure of 600kPa or
more;
- A boiler is now referred to as a steam generator;
- The old regulations required that only vessels manufactured
according to certain international standards may be sold and used in
South Africa. The regulations then listed a number of codes which
included International, French, Japanese
and other codes. The new regulations require that all pressure
equipment sold and used in South Africa must conform to the
requirements contained in the South African National Standard 347.
The only exclusion to this rule would be imported vessels that were
manufactured in compliance with the full ASME (American Society of
Mechanical Engineers) Code of Construction;
- According to the new regulation the importer assumes the
liability and responsibility of the manufactures in terms of these
regulations. This in effect means that the company selling equipment
that does not conform to the requirements as stated in the point
above could be held liable by the Department of Labour should it be
found after an incident that they sold equipment which did not
conform to the minimum legal requirement;
- Manufactures of pressure equipment now also has a legal duty to
inform the Department of Labour should they become aware of any
latent defect in equipment manufactured and sold by them. A typical
example would be when they were informed of the rupture or failure
of pressure equipment manufactured or sold by them. The notification
given to the Department of Labour should also state the measures
implemented by them as to correct the defect;
- The new regulation requires that the user (Person who uses and
gets the benefit from the use of the equipment) must ensure that a
certificate issued by the manufacturer which certifies that the
equipment was designed and manufactured in accordance with the
relevant health and safety standards is available on site.
Legislation can normally not be made retrospective and it could be
assumed that pressure equipment manufactured according to the
previously incorporated codes of good practice would still be
regarded as safe for use. What about the older pressure equipment
for which no manufacturer documentation is available? The new
regulation makes provision for a verification certificate to be
issued by an AIA. It could therefore be assumed that employers who
lost or just never obtained these documents will have to obtain the
services of an AIA to issue a certificate stating that the pressure
equipment has been manufactured to acceptable standards and is safe
for use. Although the new regulations states that some of the new
requirements will not apply to pressure equipment installed prior to
the promulgation of these regulations, no mention is made that this
specific regulation does not apply to older equipment. Time will
tell whether or not this was the intention on the part of the
Department of Labour; and
- The same would apply to any gas system (Assembly of tubes, pipes
or similar ducts, fittings and valves for the reticulation,
circulation and conveyance of gas). A typical example would be the
gas piping system installed in a laboratory, kitchen or other
workplace. Again the new regulation does not exclude older
installations and it could therefore be assumed that these
certificates are also required for older installation. Again time
will tell whether or not this was the intention on the part of the
Department of Labour.
In our next Safety Though we will discuss the new regulations further
with special attention being given to the new requirements pertaining to
inspections and pressure testing of pressure equipment.
The team at SafeNet
SafeNet (Africa) Tel: (021) 9461261 Fax 086 627 5424
e-mail:
admin@safenetafrica.co.za
Website:
http://www.safenetafrica.co.za
New Pressure Equipment Regulations In last weeks Safety thought
(above) we
started discussing the more important legal requirements contained in
the new Pressure Equipment Regulations, 2009 as promulgated by the
Department of Labour in Government Gazette notice number R734 dated the
15th of July 2009. I may have confused some in that I in last weeks
Safety Thought referred to Registered Persons as those persons
conducting the bulk of the tests and inspections on pressure vessels
used in industry. These persons are also referred to as Competent
Persons or “CPs” as this is the terminology used by the South African
Institute of Welding (SAIW). SAIW has been tasked by the Department of
Labour to set the examinations and register these persons. On proof of
registration with the SAIW the Department of Labour will register them
on their database and regard them as competent to perform certain tests
and inspections on pressure systems.
The new regulations however refer to these persons as Authorized
Persons. Irrespective of the terminology used these are the persons who
currently do the bulk of all inspections and tests on pressure systems.
Currently there are only 5 AIAs in the Western Cape compared to the many
Authorised / Competent / Registered Persons active in the Western Cape.
The following requirements as per the new regulations may also be of
importance:
- The provision in the old Vessel under Pressure Regulations, 1996
which required that all steam generators (Boilers) and pressure
vessels be inspected and tested after installation and before use
remain unchanged;
- The new regulations requires that all piping (Pipes, tubes or
flexible pressure hose elements intended for the transportation or
distribution of any fluid at a pressure of 50kPa or more) must be
inspected and be tested by the manufacturer / installer after
manufacturing, installation, modifications or repairs were done.
Category 1 equipment as categorized in the South African National
Standard 347 is excluded from this provision. This in effect will
mean that many piping systems will have to be pressure tested after
installation and before commissioning;
- The old regulations require that all pressure vessels
irrespective of the type be inspected and pressure tested every 36
months. The new regulations require that:
- Fire–tube steam generators be subjected to an external
inspection at intervals not exceeding 12 months. A hydraulic
pressure tests and crack detection test of all critical welds
must be performed at intervals not exceeding 36 months; and
- All other pressure vessels and steam generators must be
subjected to an internal, external inspection and hydraulic
pressure tests at intervals not exceeding 36 months. All of the
above inspections and tests must be performed by
Department of Labour ApprovedInspection Authorities as explained
in our previous
Safety Thought. It should however be noted that this legal
requirement will only come into effect on the 1st of April 2011.
The reason for this is merely to give companies the opportunity
to register and become SANAS accredited within a reasonable
time. It will also allow the Department of Labour some time to
facilitate this process and issue registration documents.
Category 1 equipment as categorized in the South African
National Standard 347 may however be inspected by the user
(Owner or person who gets the benefit from the use of the
equipment). As per the previous regulations a record which will
contain detail on the inspections, tests and modifications done
should be kept and be available on site;
- As with the old regulations, users of pressure vessels which
contain a non corrosive substance can still approach a Department of
Labour Approved AIA for permission not to conduct any internal
inspections and pressure testing on these vessels. Typical examples
will be vessels filled with refrigeration substances. The new
regulations however states that the permission granted will only be
valid for a period not exceeding 9 years. It could therefore be
assumed that the owners of these vessels will be required to every 9
years drain the liquid for the vessels and get an internal
inspection and pressure test done;
- All piping and pipe lines must be inspected at intervals as
prescribed by the relevant in-service health and safety standard or
as per the risk based inspection program implemented. Equipment
classified by the South African National Standard 347 as Category II
equipment and higher could be inspected and be declared safe by the
Competent Person for Machinery (Factory Engineer or Maintenance
Manager) as appointed under General Machinery Regulation 2(1);
- Employers may as an alternative to the 36 monthly inspections
implement a risk-based inspection management system which should
conform to the safety standard incorporated under the regulation. In
the absence of having studied the safety standard in full it is not
100% clear what such a risk-based inspection management system will
entail. It is however my opinion that it may be an option only
exercised by larger employers as the regulations states that such a
risk-based inspection management system must be verified by an
accreditation body such as SANAS and be accredited in terms of ISO
17021;
- As with the old regulations employers will be required to keep
record of all the above mentioned inspections, tests or exemptions
granted; and
- The manufacturer or importers of pressure equipment are legally
obliged to when selling equipment provide the client with the
instructions and safety information relating to:
- Mountings, including the assembling or different pieces of
the equipment;
- Putting the equipment in service; and
- Maintenance, including checks to be performed.
The team at SafeNet
SafeNet (Africa) Tel: (021) 9461261 Fax 086 627 5424
e-mail:
admin@safenetafrica.co.za
Website:
http://www.safenetafrica.co.za
Question 8.1
An employee is required to work in a refrigerated
environment in which the actual dry-bulb temperature is
below 0°C.
8.1.1 State THREE items of protective clothing the employee
must be provided with.
Answer: ER 2 (2) (b) (i) to (vi)
Question 8.1.2
What is the maximum exposure of the employee where
the temperature is between 0°C and -18°C.
Answer: ER 2 (2) (a) No Limit.
Question 8.1.3
what is the maximum exposure of the employee where
the temperature is between -18° and -34°.
Answer: ER 2 (2) (a) 50 min/hour
Question 8.2
With a view to the emergency evacuation of indoor
workplaces without natural lighting or where persons
habitually work at night, the employer shall provide
emergency sources of lighting in such workplaces.
Question 8.2.1
What is the minimum illuminance required during
emergency evacuation.
Answer: ER 3 (4) 0,3 Lux
Question 8.2.2
To determine whether the illuminance complies with the
prescribed requirement, where will you take the
measurement of the illuminance referred to in Question 8.2.1?
Answer: ER 3 (4) At floor level.
Question 8.2.3
What must the minimum illuminance be where
machinery or a process has to be shut down before
evacuating the workplace?
Answer: ER 3 (4) 20 Lux.
Question 8.2.4
How soon must the emergency source of lighting be
activated?
Answer: ER 3 (5) Within 15 seconds
Question 8.2.5
How long must the emergency source of lighting last?
Answer: ER 3 (5) (b) To last long enough for evacuation.
-----------------------------------------------
Jorge Pereira (Cert Eng)
Question 4
A hollow drive shaft is to be used when it is connected to a water
pump delivering 1 120 kW at 115 r/min. The maximum allowable
shear stress for the shaft material is 54 MPa and the maximum
torque to be transmitted by the shaft is 1,3 times the mean
torque. The modulus of rigidity, G = 80 GPa. Calculate the
following:
4.1.1 The internal and external diameters for a diameter ratio
of 2:1
4.1.2 The twist in the shaft over a length of 3 m when
transmitting the maximum torque
Answer: Please download the newsletter for the fully worked answer.
Graff Electric Lighting Works - A Glimmer of Light:
by Dennis Palser, Past City Electrical Engineer of Cape Town
The reason for the relatively late introduction of electricity supply
to the municipality of Cape Town itself could well have been due to a
number of factors. Firstly, there was a well-established gas lighting
system in the City that was introduced as far back as 1847, and
secondly, the more well-to-do citizens of the day presumably resided in
the southern suburbs. Perhaps more importantly was the apparent
opposition displayed to this new form of lighting by a number of
prominent and influential citizens holding public office in the City at
the time. Be that as it may, the initial idea of providing electricity
for lighting purposes in Cape Town appears to have first been mooted
back in 1880 by the then Hydraulic Engineer of the Cape Colony, Mr John
Gamble. On being requested to investigate the various sources of water
supply he suggested that water turbine-driven generators could make use
of the power in the water that would flow down into the City's main
service reservoir in Oranjezicht from a proposed new catchment reservoir
to be constructed on the top of Table Mountain. This idea was supported
by Sir John Woodhead who also proposed that an interconnecting tunnel be
constructed through the mountain. But another fifteen years was to pass
before this early idea came to fruition on a windy Saturday evening in
April 1895.
For it was on the evening of this historic day, the 13 April 1895, just
one hundred years ago, that the then Mayor, Mr George Smart, officially
inaugurated the City's first power station on the banks of the Molteno
service reservoir in Oranjezicht, on the lower slopes of Table Mountain,
thereby also effectively establishing the City's electricity undertaking
and embarking upon an ambitious scheme to light the City by means of
electricity.
Although the practical implementation of this scheme was apparently
initiated by a councillor of the time, Chevalier T J O'Reilly, it was
mainly through the efforts of another councillor while Mayor, namely the
Hon D P De Villiers Graaff, that the scheme was eventually undertaken
despite strenuous opposition from some quarters, particularly from
another prominent and wealthy citizen of the day, Mr J C Hofmeyr. Mr
Hofmeyr served as a councillor for some 30 years and was Mayor in 1878.
He was well-known for his thrifty nature and inevitably opposed any
expenditure that he considered would lead to an increase in rates. But
notwithstanding this opposition the scheme was finally adopted. In view
of the valuable services and unsparing devotion of time and attention
displayed by the Hon D P De Villiers Graaff in getting this scheme off
the ground the Council unanimously resolved that the works be named the
Graaff Electric Lighting Works in his honour.
The Inaugural Ceremony
The inauguration of the new Graaff Electric Lighting Works was
extensively reported on in the local press of the day, and the following
are a few extracts from the Cape Times of Monday, 15 April 1895.
On Saturday evening the ceremony of turning on the electric light
for the first time took place with some display of civic pomp. The
initial part of the proceedings was enacted at the Generating Station,
near the Molteno Reservoir, where at about a quarter to seven o'clock, a
small assemblage gathered, headed by Mr George Smart, the Mayor of Cape
Town. Owing to the station being a considerable distance from the town,
and to the fact that a south-easter of medium strength was blowing, the
gathering was not so large as otherwise would doubtless have been the
case.
After one or two short speeches the Mayor formally named the works
"The Graaff Electric Lighting Works", by which title he declared he
wished the works thereafter to be known.
The Mayor at this stage broke a bottle of champagne over one of
the turbines. ... The act of christening was greeted with applause,
amidst which the machinery was slowly set in motion, and the Mayor
having briefly explained the nature of the works, the assemblage, amidst
mutual and warm congratulations, adjourned to the Town House in
Greenmarket Square. The party arrived at the Town House at about
half-past seven, and the vicinity of the Town House was crowded by a
very large assemblage of citizens, while the steps and parapet were
lined with a guard of the Fire Brigade, who lent to the scene a
picturesque appearance.
At a given signal the front and interior of the old and historical
building were lit up by a blaze of light. Above the balcony was
displayed the legend 'Success to the Graaff Electric Lighting Works',
and the whole scene, during which cheers were given by the multitude for
the Mayor, was one of much splendour. The Mayor, in addressing the huge
assemblage, said that the installation of the electric light that
evening constituted the first part of that memorable programme
introduced to the citizens of Cape Town during the Mayoralty of the Hon.
Mr Graaff.... Well they now had the initial part of the installation;
but he would tell them that during the present year fifty additional
lamps would be erected in the city, while a further fifty were to be
added in the year 1896.
Since the initial contract was for the installation of 450 lamps
these additional lamps would significantly add to the public lighting
system in the City. In continuing his speech the Mayor paid tribute to
Mr Gamble, who had first suggested the construction of the reservoir on
the top of Table Mountain, and Councillor Woodhead, who had suggested
the construction of the tunnel down to the Molteno Reservoir.
And having carried out these works, and being thus in the
possession of valuable 'power', a resolution was brought forward in the
Council providing for the use of the power in installing an
electric-lighting system. Now they claimed for Mr Graaff that from the
time that resolution was adopted he set himself to work, heart and soul,
to carry it out. He turned a minority to his way of thinking, and the
result was that at last a tender for the works was accepted.
The Mayor then went on to complement the contractor, the firm of
Siemens and Halske of Berlin, and the Council's electrical engineer, Mr
E G Jones, who he mentioned "had come out from one of the best
works in England". Apparently Mr Jones was appointed to the post of
Electrical Engineer to the Council on 12 September 1894, some six months
before the official opening in order to supervise the contract.
The Mayor also reminded the public that the works had cost the City
nothing as regards engineering expenses as these had been borne
personally by Mr Graaff in a spirit of "true civic patriotism". In his
response Mr Graaff thanked the Council for its loyalty in supporting the
scheme and for honouring him by associating his name with the works.
After several more congratulatory speeches the formal proceedings
concluded, with Adderley Street and the surrounding thoroughfares
illuminated for the first time by means of electric lamps. The crowd
then dispersed and strolled through the streets "enjoying the welcome
novelty of the new light".
The Power Station Plant
The power station plant initially consisted of two 150 kW direct current
generators, more commonly known as dynamos, each being driven through a
special clutch by either a water powered Pelton wheel or a reciprocating
steam engine. In the early stages only the steam plant was used since a
supply of water was not yet available. But on the completion of the
catchment reservoir on top of Table Mountain in 1897 - appropriately
named the Woodhead reservoir - water power became available for the
first time to drive the Pelton wheels, or turbines as they were rather
loosely referred to at times.
Construction of the Molteno service reservoir itself was started as far
back as 1877 and was only completed in 1886. It was the third reservoir
to be constructed in the area and by far the largest, with a capacity of
41 million gallons (about 186 megalitres) of water.
There were two buildings on the site, namely the main building housing
the boilers and generating plant, and an adjacent smaller building
bordering onto Molteno Road that was used for the storage of coal. The
main building was divided into two sections, with one section containing
the steam engines, dynamos and water turbines (southern end), and the
other accommodating the boiler plant. A 35 metre high brick chimney
stack stood adjacent to the boiler house wall, abutting onto the smaller
coal store. A coco-pan rail interconnected the northern ends of the two
buildings to facilitate the transport of coal from the coal store to the
boiler house. The plant was run for the first year by the contractor,
Siemens and Halske, but on 11 April 1896 the Council elected to take
over the operation of the works itself.
- I won't stop bugging you until I get the address of your home
page.
- You fascinate me more than the Fundamental Theorem of Calculus.
- Since distance equals velocity times time, let's let velocity
and time approach infinity, because I want to go all the way with
you.
- My love for you is like a concave up function because it is
always increasing.
- Let's convert our potential energy to kinetic energy.
- Want to come back to my room?... and see my 300mHz Pentium II?
- How about me and you go back to my place and form a covalent
bond?
- We're as compatible as two similar Power Macintoshes.
- Why don't we measure the coefficient of static friction between
me and you?
- Wanna see the programs in my HP?
- Your body has the nicest arc length I've ever seen.
- You're hotter than a bunsen burner set to full power!
- I'd like to browse through your clothes like I browse through
Netscape.
- Hey baby, let's make a stress-strain curve together.
- your three year old son asks why the sky is blue and you try to
explain atmospheric absorption theory.
- your watch has more buttons than your telephone and more
computing power than a 300 Mhz Pentium.
- you have a non-technical vocabulary of 800 words.
- you know the second law of thermodynamics but not your shirt
size.
- someone tells you its a nice day, and you respond with "it's70
degrees Fahrenheit, 25 degrees Celsius, and 298 degrees Kelvin."
- you know the ABCs of Infrared from A to B.
- you make 4 sets of drawings (with seven revisions) before making
a bird bath.
- politically correct people call you "organizationally
challenged."
|
|